Print Version

            Following is a comparison table of RON digital scales:
            Crane scale and dynamometer features and functions.


FEATURE / FUNCTION (in alphabetical order)
Click on each feature / function for its explanation
2000-S 2000-H 2125-S 2125-H 2150-S 2150-H 2501-S 2501-H 3025 3050
ACCURACY - Standard 0.1% of full scale + + + + + + + + + +
ACCURACY - Improved 0.05% of full scale + improved resolution (see dimension tables) Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
ANALOG OUTPUT 4 to 20 mA ; 0-1V - - Opt. Opt. Opt. Opt. - - Opt. Opt.
BATTERIES - Disposable + + + + + + + + + +
BATTERIES - Rechargeable + a charger to charge the batteries when inside the indicator Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
BATTERIES - Low battery warning + + + + + + + + + + + +
BAUD RATE - User-selectable - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
CABLE - spare cable. In 15ft/5m increments Opt. Opt. Opt. Opt. Opt. Opt. - - - -
CABLE - Longer extension cable. In 15ft/5m increments Opt. Opt. Opt. Opt. Opt. Opt. - - - -
CALIBRATION - By the user + + + + + + + + + +
CAPACITY - max. 300t 32t 300t 32t 300t 32t 300t 32t 10t 10t
CASES - Carrying cases Opt. - Opt. - Opt. - Opt. - - -
CLIP - Indicator belt clip Opt. Opt. - - - - Opt. Opt. - -
DATA LOGGER - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
DIGITAL OUTPUT (see RS-232 and BAUD RATE)                    
DISPLAYS - Additional, with cable connection. 2"/50 mm - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
DISPLAYS - Double, back-to-back - - - - - - - - - Opt.
DISPLAYS - Shape and digit size:(5 digits) Hand-held with cable. 0.5"/12.5mm + + - - - - - - - -
Hand-held wireless 0.5"/12.5mm - - - - - - + + - -
Removable 1"/25mm - - + + - - - - - -
Removable 2"/50mm - - - - + + - - - -
Integral 1"/25mm - - - - - - - - + -
Integral 2"/50mm - - - - - - - - - +
HEAT SHIELD - - - - - - Opt. Opt. - -
IP 65 NEMA 4 + + + + + + + + + +
IP 67 Special high seal connectors Opt. Opt. Opt. Opt. Opt. Opt. - - - -
IP 68 Load cell with underwater capability Opt. Opt. Opt. Opt. Opt. Opt. - - - -
MAX. VALUE (see PEAK HOLD)                    
NUMBER OF MEASUREMENTS PER SECOND:1 + + + + + + + + + +
NUMBER OF MEASUREMENTS PER SECOND: 2/3/4/5/6/7/8/20/30, factory set. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
OVERLOAD DETECTION - 2 levels + + + + + + + + + +
PEAK HOLD + + + + + + + + + +
REAL TIME CLOCK - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
RF (see WIRELESS SYSTEM)                    
RS-232 continuous data output or on demand, user-selectable - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
SET POINTS - User-adjustable - - 2 Opt. 2 Opt. 2 Opt. 2 Opt. 2 Opt. 2 Opt. 2 Opt. 2 Opt.
SLEEP MODE + + + + + + + + + +
SWIVEL HOOK - - - - - - - - - Opt.
TARE + + + + + + + + + +
TEMPERATURE RANGE
      -13°F to + 175°F
      -25°C to + 80°C
+ + + + + + + + + +
TOTALIZER - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
UNITS User-selectable - - Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt.
Factory-set + + + + + + + + + +
WATER - load cell with underwater capability
(see IP 68)
                   
WIRELESS SYSTEM - - - - - - + + - -
ZERO + + + + + + + + + +

Opt.= Option V = ÷02V H = Hook Type
+ = Standard feature A = 4÷20mA S = Shackle Type
  - = Not available RF = Wireless (RF)