Welcome to RON Crane Scales. Last update:4.7.2009
|
|
 |
 |
|
|
|
 |
Products »
Load cells »
Ron 4000
Ron 4000
Load Cell with built-in Amplifier
|  |
Advantages
Description
The RON series includes Crane Scales, Dynamometers and Tension Load Cells.
The RON 4000 is a loadcell with a built-in analog amplifier. This loadcell is specially designed to transmit load or force information to a controller/computer, as part of controlled tensioning and tension measurement.
For example, RON 4000 electronic Load Cells serve as tension Load Cells for tension measurement and controlled tensioning of rubber belt conveyors or continuous weighing of steam piping in a power station to detect water condensation in pipes and drain them when the max. permitted level is reached.
The unique perpendicular hole structure of the loadcells neutralizes external moments and thus improves safety and accuracy.
The small and light loadcells ensure portability and low headroom loss for any application.
RON Crane Scales, Dynamometers and electronic Load cells are used for weighing during lifting, overload prevention and tension, force and load measurement.
All RON Load Cells are factory-tested and supplied with a test certificate.
Specifications | Options |
safety factor : designed to 5:1. proof load : each system proof-loaded to 200% of capacity (certified) up to a test force of 400t. load cell material : high-strength, aerospace quality alloy steel, polyurethane coated. linearity : 0.1% f.s. input : 6 to 12vdc output : 0 to 2v. option 4 to 20ma option 0 to 2v + 4 to 20ma cable : supplied with 9' (3m) cable. temperature range : -15°f to +175°f (-25°c to +80°c). safety factor : designed to 5:1. proof load : each system proof-loaded to 200% of capacity (certified) up to a test force of 400t. load cell material : high-strength, aerospace quality alloy steel, polyurethane coated. linearity : 0.1% f.s. input : 6 to 12vdc output : 0 to 2v. option 4 to 20ma option 0 to 2v + 4 to 20ma cable : supplied with 9' (3m) cable. temperature range : -15°f to +175°f (-25°c to +80°c). |
|
Environmental : Weatherproof, NEMA 4, IP 65. Calibration : Supplied with approximate calibration (Final calibration is performed by the customer, after connecting the load cell to the measuring / control system). Zero load = 0±0.01v, 4±0.2mA. Full load = 2±0.1v, 20-1mA. Max. Input Current : 100mA Wiring : Input voltage (6 to 12VDC) Red Common Black Output V White Output A Green Body Without insulation |
|
4 to 20 mA 0 to 2v + 4 to 20 mA Fatigue rated load cell IP 68 Load cell with underwater capability.
|
| RON 4000 | | | Optional carrying case | | | 15.08.07 |
Dimensions Table and Drawing

| Cat no. | Full range | Load cell weight | H1 (max.) | H2 (max.) | B (max.) | Ø D 1 (max.) | Ø D 2 (min.) | Matching anchor shackle size* | | tons | kgs | lbs | mm | inch | mm | inch | mm | inch | mm | inch | mm | inch | inch | | S-005 | 0.5 | 0.4 | 0.9 | 125 | 4.9 | 92 | 3.7 | 16 | 0.7 | 31 | 1.3 | 17 | 0.66 | 1/2, 7/16, 3/8 | | S-01 | 1 | 0.4 | 0.9 | 125 | 4.9 | 92 | 3.7 | 16 | 0.7 | 31 | 1.3 | 17 | 0.66 | 1/2, 7/16, 3/8 | | S-02 | 2 | 0.4 | 0.9 | 125 | 4.9 | 92 | 3.7 | 16 | 0.7 | 31 | 1.3 | 17 | 0.66 | 1/2, 7/16, 3/8 | | S-03 | 3 | 0.4 | 0.9 | 140 | 5.5 | 100 | 4 | 19 | 0.75 | 38 | 1.5 | 21 | 0.82 | 5/8, 1/2 | | S-05 | 5 | 0.6 | 1.3 | 150 | 5.9 | 105 | 4.2 | 26 | 1 | 45 | 1.75 | 23 | 0.9 | 3/4, 5/8 | | S-10 | 10 | 1.5 | 3.3 | 200 | 7.9 | 135 | 5.3 | 41 | 1.6 | 63 | 2.5 | 36 | 1.4 | 1 1/4, 1 1/8, 1 | | S-12 | 12.5 | 1.5 | 3.3 | 200 | 7.9 | 135 | 5.3 | 41 | 1.6 | 63 | 2.5 | 36 | 1.4 | 1 1/4, 1 1/8, 1 | | S-15 | 15 | 2.5 | 5.5 | 225 | 8.8 | 145 | 5.7 | 53 | 2.1 | 75 | 3 | 40 | 1.55 | 1 3/8 | | S-20 | 20 | 2.5 | 5.5 | 225 | 8.8 | 145 | 5.7 | 53 | 2.1 | 75 | 3 | 40 | 1.55 | 1 3/8 | | S-25 | 25 | 3.5 | 7.7 | 240 | 9.4 | 150 | 5.9 | 58 | 2.3 | 87 | 3.4 | 44 | 1.7 | 1 1/2 | | S-30 | 30 | 3.5 | 7.7 | 240 | 9.4 | 150 | 5.9 | 58 | 2.3 | 87 | 3.4 | 44 | 1.7 | 1 1/2 | | S-40 | 40 | 7.7 | 17 | 320 | 12.6 | 195 | 7.7 | 71 | 2.8 | 115 | 4.5 | 60 | 2.3 | 2, 1 3/4 | | S-50 | 50 | 7.7 | 17 | 320 | 12.6 | 195 | 7.7 | 71 | 2.8 | 115 | 4.5 | 60 | 2.3 | 2, 1 3/4 | | S-80 | 80 | 18 | 40 | 405 | 16.9 | 255 | 10 | 97 | 3.8 | 145 | 5.7 | 76 | 3 | 2 1/2 | | S-125 | 125 | 27 | 60 | 460 | 18.2 | 290 | 11.5 | 121 | 4.8 | 165 | 6.5 | 81 | 3.18 | CROSBY No. 2160 125t | | S-200 | 200 | 55 | 121 | 575 | 22.6 | 350 | 13.8 | 145 | 5.7 | 210 | 8.3 | 106 | 4.2 | CROSBY No. 2160 200t | | S-250 | 250 | 103 | 227 | 850 | 33.5 | 510 | 20.1 | 178 | 7.0 | 254 | 10 | 133 | 5.2 | CROSBY No. 2140 250t. Or No. 2160 300t | | S-300 | 300 | 103 | 227 | 850 | 33.5 | 510 | 20.1 | 178 | 7.0 | 254 | 10 | 133 | 5.2 | CROSBY No. 2160 300t |
* USE SHACKLES WITH S.W.L. (SAFE WORKING LOAD) EQUAL TO, OR GREATER THAN SYSTEM'S FULL RANGE. * The company reserves the right to make changes without notice. |
 |
| |
 |
Back to top